      淺談框架結(jié)構(gòu)設(shè)計(jì)的心得體會(huì)

      摘要 框架結(jié)構(gòu)是最常見(jiàn)的承重結(jié)構(gòu)體系,本文從框架結(jié)構(gòu)概念設(shè)計(jì)、內(nèi)力和位移的計(jì)算機(jī)計(jì)算、構(gòu)造要求等要點(diǎn)出發(fā),介紹鋼筋混凝土框架結(jié)構(gòu)的設(shè)計(jì)要點(diǎn)及注意事項(xiàng)。特別是在框架結(jié)構(gòu)內(nèi)力和位移的計(jì)算機(jī)計(jì)算方面,結(jié)合自己的設(shè)計(jì)經(jīng)驗(yàn),針對(duì)“剛性樓板假定”、“偶然偏心”、“結(jié)構(gòu)扭轉(zhuǎn)效應(yīng)”等主要結(jié)構(gòu)計(jì)算參數(shù)的選取提出了筆者的一些見(jiàn)解。另外,還從框架梁、框架柱、節(jié)點(diǎn)等構(gòu)造要求列舉了主要的注意事項(xiàng)。

      關(guān)鍵詞 框架結(jié)構(gòu) 概念設(shè)計(jì) 內(nèi)力 位移 構(gòu)造要求

      框架結(jié)構(gòu)是由橫梁和立柱組成的桿件體系,是最常見(jiàn)的承重結(jié)構(gòu)體系。由于框架結(jié)構(gòu)柱網(wǎng)布置靈活,能獲得較大的使用空間,在辦公樓、教學(xué)樓、住宅樓、公寓以及商業(yè)建筑中常常采用。下面結(jié)合框架設(shè)計(jì)過(guò)程和實(shí)際工程設(shè)計(jì)經(jīng)驗(yàn),談一談鋼筋混凝土框架結(jié)構(gòu)的設(shè)計(jì)要點(diǎn)及注意事項(xiàng)。

      一、框架結(jié)構(gòu)概念設(shè)計(jì)

      一個(gè)合格的結(jié)構(gòu)設(shè)計(jì)人員應(yīng)該清楚地認(rèn)識(shí)到框架結(jié)構(gòu)設(shè)計(jì)中,概念設(shè)計(jì)與結(jié)構(gòu)措施的至關(guān)重要性。

      首先我們要控制房屋適用高度和結(jié)構(gòu)高寬比,若結(jié)構(gòu)的高寬比大,則傾覆力矩也大。為了幫助設(shè)計(jì)者在初步設(shè)計(jì)階段根據(jù)結(jié)構(gòu)高度和結(jié)構(gòu)體系確定比較合理而經(jīng)濟(jì)的平面尺寸,宏觀控制結(jié)構(gòu)的剛度、穩(wěn)定和承載力,《高層建筑混凝土結(jié)構(gòu)技術(shù)規(guī)程》(JGJ3-2010)規(guī)定了框架結(jié)構(gòu)的高寬比限值。

      其次是結(jié)構(gòu)布置簡(jiǎn)單規(guī)則均勻。結(jié)構(gòu)簡(jiǎn)單包含有三層意思,即(1)結(jié)構(gòu)的類(lèi)別劃分,計(jì)算模型清楚;(2)各結(jié)構(gòu)構(gòu)件力學(xué)功能分工,在荷載和作用下傳力路線(xiàn)直接、明確;(3)其受力、薄弱環(huán)節(jié)及抗震性能估計(jì)把握,精細(xì)分析程序可靠。這就要求工程師在熟練運(yùn)用計(jì)算機(jī)設(shè)計(jì)程序的同時(shí),更要掌握必要的框架結(jié)構(gòu)簡(jiǎn)化估算方法。結(jié)構(gòu)規(guī)則均勻要求含平面和立面兩部分,包括剛度、承載力和傳力途徑三個(gè)方面。要求框架結(jié)構(gòu)在可能的情況下,在豎向建筑造型和結(jié)構(gòu)布置上均勻,剛度、承載力和傳力途徑均無(wú)突變,從而限制應(yīng)力集中、過(guò)大變形和敏感薄弱部位的出現(xiàn);在建筑平面上規(guī)則,結(jié)構(gòu)布置均勻,盡量減少里出外進(jìn)、凹凸不平,盡量避免部分結(jié)構(gòu)超強(qiáng)造成結(jié)構(gòu)的相對(duì)薄弱部位,該強(qiáng)的強(qiáng),該弱的弱;盡量使荷載和作用能用短而直接的途徑傳播,盡量使質(zhì)量中心和剛度中心重合或接近。

      最后是剛?cè)徇m度。事實(shí)表明,結(jié)構(gòu)的變形越小,地震的危害就越小。但是不能得出剛度越大越好的結(jié)論,因?yàn)閯偠扔?,地震作用愈大,材料用量?huì)增加。此外,結(jié)構(gòu)振動(dòng)和變形的大小不僅和結(jié)構(gòu)剛度有關(guān),還與場(chǎng)地土有關(guān).當(dāng)結(jié)構(gòu)自振周期與場(chǎng)地土的卓越周期接近時(shí),建筑物的地震反應(yīng)會(huì)加大,無(wú)論振動(dòng)變形還是地震力都會(huì)加大。因此,對(duì)于框架結(jié)構(gòu)設(shè)計(jì),不能做出“剛一些好”還是“柔一些好”的簡(jiǎn)單結(jié)論,應(yīng)該結(jié)合結(jié)構(gòu)的具體高度、場(chǎng)地條件等進(jìn)行綜合判斷。

      二、框架結(jié)構(gòu)內(nèi)力和位移的計(jì)算機(jī)計(jì)算

      隨著計(jì)算機(jī)的迅猛發(fā)展和廣泛應(yīng)用,使得結(jié)構(gòu)計(jì)算軟件在結(jié)構(gòu)設(shè)計(jì)中得到大量的應(yīng)用,結(jié)構(gòu)設(shè)計(jì)人員的工作效率提高,也使得一部分結(jié)構(gòu)設(shè)計(jì)人員對(duì)結(jié)構(gòu)計(jì)算軟件產(chǎn)生過(guò)度依賴(lài),以為結(jié)構(gòu)計(jì)算軟件滿(mǎn)足,結(jié)構(gòu)設(shè)計(jì)就是合理、安全的,有的設(shè)計(jì)人員甚至不假思索、調(diào)整,直接以軟件自動(dòng)生成的施工圖作為實(shí)際施工圖,殊不知結(jié)構(gòu)計(jì)算軟件畢竟是我們的工具,結(jié)構(gòu)設(shè)計(jì)人員應(yīng)該對(duì)結(jié)構(gòu)軟件中各種參數(shù)進(jìn)行合理選取,并對(duì)計(jì)算結(jié)果的合理性作出判斷。

      1.“對(duì)所有樓層采用剛性板假定”該如何選擇?!督ㄖ拐鹪O(shè)計(jì)規(guī)范》(GB 50011-2010)和《高層建筑混凝土結(jié)構(gòu)技術(shù)規(guī)程》(JGJ3-2010)均要求,在計(jì)算結(jié)構(gòu)的位移比時(shí),要采用剛性樓蓋。因此,設(shè)計(jì)人員在計(jì)算此項(xiàng)指標(biāo)時(shí)應(yīng)考慮“強(qiáng)制執(zhí)行剛性板假定”。結(jié)構(gòu)的位移比是反映結(jié)構(gòu)扭轉(zhuǎn)效應(yīng)的一項(xiàng)重要指標(biāo),為了避免由于局部振動(dòng)的存在而影響結(jié)構(gòu)位移比的正確計(jì)算,規(guī)范規(guī)定在附性板假定下計(jì)算結(jié)構(gòu)的位移比。這里需要說(shuō)明的是,在計(jì)算結(jié)構(gòu)的內(nèi)力和配筋時(shí),則宜將此選項(xiàng)去掉。

      2.何時(shí)考慮“偶然偏心”。《高規(guī)》第3.3.3條規(guī)定:計(jì)算單向地震作用時(shí)應(yīng)考慮偶然偏心的影響。附加偏心距可取與地震作用方向垂直的建筑物邊長(zhǎng)的5%。

      控制偶然偏心的主要目的是控制結(jié)構(gòu)的扭轉(zhuǎn)效應(yīng)。當(dāng)結(jié)構(gòu)在偶然偏心作用下的位移比大于1.2時(shí),則說(shuō)明該結(jié)構(gòu)的質(zhì)量和剛度的分布比較不均勻,抗扭轉(zhuǎn)的能力比較差。對(duì)于高層建筑,即便是均勻、對(duì)稱(chēng)的結(jié)構(gòu),也應(yīng)考慮偶然偏心的影響;對(duì)于多層建筑,則可以不考慮偶然偏心的影響。

      3.結(jié)構(gòu)扭轉(zhuǎn)效應(yīng)的判斷。結(jié)構(gòu)的周期比是判斷結(jié)構(gòu)扭轉(zhuǎn)效應(yīng)的重要指標(biāo)之一,《高規(guī)》第4.3.5條規(guī)定:結(jié)構(gòu)以扭轉(zhuǎn)為主的第一自振周期Tt與平動(dòng)為主的第一自振周期Tl之比,A級(jí)高度高層建筑不應(yīng)大于0.9,目前的程序沒(méi)有直接輸出結(jié)構(gòu)的周期比,需要設(shè)計(jì)人員根據(jù)程序的計(jì)算結(jié)果自行計(jì)算。在確定結(jié)構(gòu)的第一平動(dòng)周期和扭轉(zhuǎn)周期時(shí)主要注意以下幾點(diǎn):(1)根據(jù)工程具體情況,確定平動(dòng)和扭轉(zhuǎn)系數(shù)所占百分比;第一平動(dòng)周期所對(duì)應(yīng)的振型應(yīng)該越單純?cè)胶?。平?dòng)與扭轉(zhuǎn)系數(shù)所占百分比為多少合適,規(guī)范并沒(méi)有說(shuō)明,應(yīng)根據(jù)具體情況而定。對(duì)于第一扭轉(zhuǎn)周期的判斷,則根據(jù)《高規(guī)》第3.4.5條的條文說(shuō)明中的解釋?zhuān)趦蓚€(gè)平動(dòng)和一個(gè)轉(zhuǎn)動(dòng)構(gòu)成的三個(gè)方向因子中,當(dāng)轉(zhuǎn)動(dòng)方向因子大于0.5時(shí),則該振型可認(rèn)為是扭轉(zhuǎn)為主的振型。(2)查看振型圖,看結(jié)構(gòu)在該振型作用下是否為整體振動(dòng)。

      三、框架結(jié)構(gòu)構(gòu)造要求

      1.框架柱構(gòu)造要求。影響框架柱延性耗能的主要因素可歸納為柱剪跨比、軸壓比和箍筋配置等,對(duì)此規(guī)范都做了具體規(guī)定,如柱剪跨比宜大于2;柱截面高寬比不宜大于3。柱剪跨比不大于2時(shí),應(yīng)按短柱進(jìn)行相關(guān)處理。

      柱可沿全高分階段改變截面尺寸和混凝土強(qiáng)度等級(jí),但不宜在同一樓層同時(shí)改變截面尺寸和混凝土強(qiáng)度等級(jí)。一、二級(jí)抗震等級(jí)框架柱的各部位以及三級(jí)抗震等級(jí)柱的底部的受力鋼筋宜采用機(jī)械連接接頭,也可采用綁扎搭接或焊接接頭;其他情況可采用綁扎搭接或焊接接頭;鋼筋連接接頭宜避開(kāi)有抗震設(shè)防要求的梁端、柱端箍筋加密區(qū)(即塑性鉸區(qū)),當(dāng)無(wú)法避開(kāi)時(shí),應(yīng)采用I級(jí)或Ⅱ級(jí)機(jī)械連接接頭,且接頭百分率不應(yīng)大于50%。

      2.框架梁構(gòu)造要求??蚣芰翰辉O(shè)彎起鋼筋,全部剪力由箍筋和混凝土承擔(dān)??蚣芰旱呐浣盥省⑴浣畈贾靡约翱拐鹪O(shè)計(jì)時(shí),梁端箍筋的加密區(qū)長(zhǎng)度、箍筋最大間距和最小直徑應(yīng)符合《混凝土結(jié)構(gòu)設(shè)計(jì)規(guī)范》、《建筑抗震設(shè)計(jì)規(guī)范》和《高層建筑混凝土結(jié)構(gòu)技術(shù)規(guī)程》的有關(guān)規(guī)定。應(yīng)當(dāng)注意,為使梁端塑性鉸區(qū)截面有比較大的曲率延性和良好的轉(zhuǎn)動(dòng)能力,成為延性耗能梁,梁端混凝土受壓區(qū)高度應(yīng)滿(mǎn)足以下要求:一級(jí)框架梁,≤0.25,二、三級(jí)框架梁,≤0.35。

      為減小框架梁端塑性鉸區(qū)范圍內(nèi)的相對(duì)受壓區(qū)高度,塑性鉸區(qū)截面底部必須配置受壓鋼筋。受壓鋼筋的面積除按計(jì)算確定外,與頂面受拉鋼筋面積的比值還應(yīng)滿(mǎn)足以下要求:一級(jí)框架梁,≥0.5,二、三級(jí)框架梁,≥0.3。

      3.節(jié)點(diǎn)構(gòu)造要求。在豎向荷載和地震作用下,框架梁柱節(jié)點(diǎn)主要承受柱傳來(lái)的軸向力、彎矩、剪力和梁傳來(lái)的彎矩、剪力。節(jié)點(diǎn)區(qū)的破壞形式為由主拉應(yīng)力引起的剪切破壞。如果節(jié)點(diǎn)未設(shè)箍筋或箍筋不足,則由于其抗剪能力不足,節(jié)點(diǎn)區(qū)出現(xiàn)多條交叉斜裂縫,斜裂縫間混凝土被壓碎,柱內(nèi)縱向鋼筋壓屈,所以應(yīng)該重視框架梁、柱節(jié)點(diǎn)核心區(qū)的設(shè)計(jì)。

      框架梁、柱節(jié)點(diǎn)核心區(qū)應(yīng)符合下列要求:

      (1)應(yīng)根據(jù)《建筑抗震設(shè)計(jì)規(guī)范》GB50011附錄D.2的規(guī)定,分別按節(jié)點(diǎn)的內(nèi)、外核心區(qū)驗(yàn)算節(jié)點(diǎn)受剪承載力;

      (2)節(jié)點(diǎn)內(nèi)核心區(qū)的配箍量及構(gòu)造要求同普通框架;

      四、結(jié)束語(yǔ)

      鋼筋混凝土框架結(jié)構(gòu)雖然相對(duì)簡(jiǎn)單,但設(shè)計(jì)中仍有很多需要注意的事項(xiàng),只有結(jié)構(gòu)設(shè)計(jì)人員既有扎實(shí)的理論功底,又有豐富的工程經(jīng)驗(yàn),并且熟練掌握各種規(guī)范,結(jié)合概念設(shè)計(jì),才能設(shè)計(jì)出既安全、可靠,又經(jīng)濟(jì)、合理的建筑物。

      第二篇:淺談鋼筋混凝土框架結(jié)構(gòu)設(shè)計(jì)的心得體會(huì)

      淺談鋼筋混凝土框架結(jié)構(gòu)設(shè)計(jì)的心得體會(huì)

      [摘要]在鋼筋混凝土結(jié)構(gòu)設(shè)計(jì)中,由于每個(gè)設(shè)計(jì)者的經(jīng)驗(yàn)不同、對(duì)規(guī)范的理解不同,因而在處理某個(gè)設(shè)計(jì)問(wèn)題時(shí),也就會(huì)采取不同的處理方法。文章對(duì)鋼筋混凝土框架結(jié)構(gòu)設(shè)計(jì)中,基礎(chǔ)、梁、柱、板四部分應(yīng)注意的問(wèn)題,分別提出若干看法。

      [關(guān)鍵詞]鋼筋混凝土結(jié)構(gòu)設(shè)計(jì);基礎(chǔ);梁;柱;板

      [作者簡(jiǎn)介]劉平湘,南寧市建筑設(shè)計(jì)院助理工程師,研究方向:結(jié)構(gòu)工程,廣西南寧, 530022

      [中圖分類(lèi)號(hào)] TU375 [文獻(xiàn)標(biāo)識(shí)碼] A [文章編號(hào)] 1007-7723(2010)05-0111-0002

      近年來(lái)越來(lái)越多的建筑物使用鋼筋混凝土結(jié)構(gòu),故鋼筋混凝土結(jié)構(gòu)在整個(gè)建筑市場(chǎng)的地位越來(lái)越重要。在鋼筋混凝土結(jié)構(gòu)設(shè)計(jì)中,由于每個(gè)設(shè)計(jì)者的經(jīng)驗(yàn)不同、對(duì)規(guī)范的理解不同,所以在處理某個(gè)設(shè)計(jì)問(wèn)題時(shí),也就會(huì)采取不同的處理方法。在這幾年的結(jié)構(gòu)設(shè)計(jì)實(shí)踐工作中,筆者積累了一些經(jīng)驗(yàn),下面就鋼筋混凝土框架結(jié)構(gòu)設(shè)計(jì)中的基礎(chǔ)、梁、柱、板四部分,在設(shè)計(jì)時(shí)應(yīng)注意的問(wèn)題,闡述一下個(gè)人觀點(diǎn)。

      一、基礎(chǔ)部分

      1.對(duì)于柱下擴(kuò)展基礎(chǔ)寬度較寬(大于4m)或地基不均勻及地基較軟時(shí)宜采用柱下條基;并應(yīng)考慮節(jié)點(diǎn)處基礎(chǔ)底面積雙向重復(fù)使用的不利因素,適當(dāng)加寬基礎(chǔ)。

      2.建筑地段較好、基礎(chǔ)埋深大于3m時(shí),應(yīng)建議甲方做地下室。當(dāng)?shù)鼗休d力滿(mǎn)足設(shè)計(jì)要求時(shí),地下室底板可不再外伸以利于防水。每隔30~40m設(shè)一后澆帶,并注明兩個(gè)月后用微膨脹混凝土澆注。設(shè)置地下室可降低地基的附加應(yīng)力,提高地基的承載力(尤其是在周?chē)薪ㄖr(shí)有用),減少地震作用對(duì)上部結(jié)構(gòu)的影響。不應(yīng)設(shè)局部地下室,且地下室應(yīng)有相同的埋深。

      3.地下室外墻為混凝土?xí)r,相應(yīng)的樓層處梁和基礎(chǔ)梁可取消。

      4.抗震縫、伸縮縫在地面以下可不設(shè),連接處應(yīng)加強(qiáng);但沉降縫兩側(cè)墻體基礎(chǔ)一定要分開(kāi)。

      5.新建建筑物基礎(chǔ)不宜深于周?chē)延谢A(chǔ)。如深于原有基礎(chǔ),其基礎(chǔ)間的凈距應(yīng)不少于基礎(chǔ)高差的2倍;否則應(yīng)打抗滑移樁,防止原有建筑的破壞。建筑層數(shù)相差較大時(shí),應(yīng)在層數(shù)較低的基礎(chǔ)方格中心的區(qū)域內(nèi)墊焦碴來(lái)調(diào)整基底附加應(yīng)力。

      6.獨(dú)立基礎(chǔ)偏心不能過(guò)大,必要時(shí)可與相近的基礎(chǔ)做成柱下條基。兩根柱的柱下條基的荷載重心和基礎(chǔ)底版的形心宜重合,基礎(chǔ)底板可做成梯形或臺(tái)階形,或調(diào)整挑梁兩端的出挑長(zhǎng)度。

      7.獨(dú)立基礎(chǔ)的拉梁宜通長(zhǎng)配筋。拉梁頂標(biāo)高宜較高,否則底層墻體過(guò)高。

      8.底層內(nèi)隔墻一般不用做基礎(chǔ),可將地面的混凝土墊層局部加厚。

      9.基礎(chǔ)底板混凝土不宜大于C3O,一是沒(méi)用;二是容易出現(xiàn)裂縫。

      二、柱子部分

      1.地上為圓柱時(shí),地下部分應(yīng)改為方柱,方便施工。圓柱縱筋根數(shù)最少為8根,箍筋用螺旋箍,并注明端部應(yīng)有一圈半的水平段。方柱箍筋應(yīng)使用井字箍,并按規(guī)范加密。角柱、樓梯間柱應(yīng)增大縱筋并全柱高加密箍筋。幼兒園不宜用方柱。

      2.原則上柱的縱筋宜大直徑、大間距,但間距不宜大于200。

      3.柱內(nèi)埋管,由于梁的縱筋錨入柱內(nèi),一般情況下僅在柱的四角才有條件埋設(shè)較粗的管。管截面面積占柱截面4%以下時(shí),可不必驗(yàn)算。柱內(nèi)不得穿暖氣管。

      4.柱斷面不宜小于450×450,混凝土不宜小于C25,否則梁縱筋錨入柱內(nèi)的水平段不容易滿(mǎn)足0.45La的要求,不滿(mǎn)足時(shí)應(yīng)加橫筋;否則在梁柱節(jié)點(diǎn)處鋼筋太密,混凝土澆筑困難。異型柱結(jié)構(gòu),梁縱筋一排根數(shù)不宜過(guò)多,柱端部縱筋不宜過(guò)密,否則節(jié)點(diǎn)混凝土澆筑困難。當(dāng)有部分矩形柱部分異型柱時(shí),應(yīng)注意異型柱的剛度要和矩形柱相接近,不要相差太大。

      5.柱應(yīng)盡量采用高強(qiáng)度混凝土來(lái)滿(mǎn)足軸壓比的限制,減小斷面尺寸。

      6.盡量避免短柱,短柱箍筋應(yīng)全高加密,短柱縱筋不宜過(guò)大。

      7.考慮到豎向地震作用,柱子的軸壓比及配筋宜留有余地。

      三、梁部分

      1.梁上有次梁處(包括挑梁端部)應(yīng)附加箍筋和吊筋,宜優(yōu)先采用附加箍筋。附加筋一般要有,但不應(yīng)絕對(duì)。規(guī)范說(shuō)得清楚,位于梁下部或梁截面高度范圍內(nèi)的集中荷載,應(yīng)全部由附加橫向鋼筋承擔(dān)。也就是說(shuō),位于梁上的集中力如梁上柱、梁上后做的梁如水箱下的墊梁不必加附加筋。位于梁下部的集中力應(yīng)加附加筋。但梁截面高度范圍內(nèi)的集中荷載可根據(jù)具體情況而定。當(dāng)主次梁截面相差不大,次梁荷載較大時(shí),應(yīng)加附加筋。當(dāng)主梁高度很高、次梁截面很小、荷載很小時(shí),如快接近板上附加暗梁,主梁可不加附加筋。還有當(dāng)主次梁截面均很大,如工藝要求形成的主次深梁,而荷載相對(duì)不大,主梁也可不加附加筋。

      2.當(dāng)外部梁跨度相差不大時(shí),梁高宜等高,尤其是外部的框架梁。當(dāng)梁底距外窗頂尺寸較小時(shí),宜加大梁高做至窗頂。梁也可偏出柱邊一較小尺寸。梁與柱的偏心可大于1/4柱寬,并宜小于1/3柱寬。

      3.梁上有次梁時(shí),應(yīng)避免次梁搭接在主梁的支座附近;否則應(yīng)考慮由次梁引起的主梁抗扭,或增加構(gòu)造抗扭縱筋和箍筋。當(dāng)采用現(xiàn)澆板時(shí),抗扭問(wèn)題并不嚴(yán)重。

      4.原則上梁縱筋宜小直徑、小間距,有利于抗裂;但應(yīng)注意鋼筋間距要滿(mǎn)足要求,并與梁的斷面相應(yīng)。箍筋按規(guī)定在梁端頭加密。布筋時(shí)應(yīng)將縱筋等距,箍筋肢距可不等。小斷面的連續(xù)梁或框架梁,上、下縱筋均應(yīng)采用同直徑的,盡量不在支座搭接。

      5.端部與框架梁相交或彈性支承在墻體上的次梁,梁端支座可按簡(jiǎn)支考慮,但梁端箍筋應(yīng)加密。

      6.挑梁宜作成等截面(大挑梁外露者除外)。與挑板不同,挑梁的自重占總荷載的比例很小,作成變截面不能有效減輕自重。變截面挑梁的箍筋,每個(gè)都不一樣,難以施工。變截面梁的撓度也要大于等截面梁。挑梁端部有次梁時(shí),注意要附加箍筋或吊筋。一般挑梁根部不必附加斜筋,除非受剪承載力不足。對(duì)于大挑梁,梁的下部宜配置受壓鋼筋以減小撓度。挑梁配筋應(yīng)留有余地。

      7.梁上開(kāi)洞時(shí),不但要計(jì)算洞口加筋,更應(yīng)驗(yàn)算梁洞口下偏拉部分的裂縫寬度。梁從構(gòu)造上能保證不發(fā)生沖切破壞和斜截面受彎破壞。

      8.挑梁出挑長(zhǎng)度小于梁高時(shí),應(yīng)按牛腿計(jì)算或按深梁構(gòu)造配筋。

      9.扁梁寬度不必過(guò)大,只要鋼筋能正常擺下及受剪滿(mǎn)足即可。因?yàn)樵趽隙扔?jì)算時(shí),梁寬對(duì)剛度影響不大。相對(duì)來(lái)講,增大鋼筋更經(jīng)濟(jì)。同時(shí)梁的上筋應(yīng)大部分通長(zhǎng)布置,以減小混凝土徐變對(duì)撓度的增大。

      10.梁寬大于350時(shí),應(yīng)采用四肢箍。

      四、現(xiàn)澆板部分

      1.板的鋼筋宜采用大直徑、大間距,但間距不大于200,間距盡量用200(一般跨度小于6.6m的板的裂縫均可滿(mǎn)足要求)。板上下鋼筋間距宜相等,直徑可不同,但鋼筋直徑類(lèi)型也不宜過(guò)多。

      2.相連幾個(gè)房間的同型號(hào)、同間距板底鋼筋宜連通。

      3.配筋計(jì)算時(shí),可考慮塑性?xún)?nèi)力重分布,將板上筋乘以0.8~0.9的折減系數(shù),將板下筋乘以1.1~1.2的放大系數(shù)。

      4.支承在外圈框架梁上的板負(fù)筋不宜過(guò)大,否則將對(duì)梁產(chǎn)生過(guò)大的附加扭距。一般來(lái)說(shuō),板厚>150時(shí)采用 φ10@200;否則用 φ8@200。

      5.當(dāng)厚板與薄板相接時(shí),薄板支座按固定端考慮是適當(dāng)?shù)?但厚板就不合適,宜減小厚板支座配筋,增大跨中配筋。

      五、結(jié)語(yǔ)

      以上是筆者在這幾年設(shè)計(jì)工作實(shí)踐中關(guān)于鋼筋混凝土框架結(jié)構(gòu)設(shè)計(jì)的幾點(diǎn)心得體會(huì),僅供設(shè)計(jì)人員和施工人員參考?!鞍倌甏笥?jì)、質(zhì)量第一”不是一句空號(hào)。這不但要求廣大設(shè)計(jì)、管理、施工和技術(shù)人員有對(duì)國(guó)家和人民極端負(fù)責(zé)的態(tài)度和獻(xiàn)身精神,而且要求他們有能勝任工作的業(yè)務(wù)水平。

      [參考文獻(xiàn)]

      [1]混凝土結(jié)構(gòu)設(shè)計(jì)規(guī)范(GB 50010-2002)[S].[2]建筑抗震設(shè)計(jì)規(guī)范(GB 50011-2001)[S].[3]高層建筑混凝土結(jié)構(gòu)技術(shù)規(guī)程(JGJ3-2002)[S].

      第三篇:鋼筋混凝土框架結(jié)構(gòu)設(shè)計(jì)的幾點(diǎn)心得體會(huì)

      鋼筋混凝土框架結(jié)構(gòu)設(shè)計(jì)的幾點(diǎn)心得體會(huì)

      張永濤 姬廣東

      (山東省冶金設(shè)計(jì)院有限責(zé)任公司 萊蕪 271104)

      摘要:在鋼筋混凝土結(jié)構(gòu)設(shè)計(jì)中,每個(gè)設(shè)計(jì)者的經(jīng)驗(yàn)不同,對(duì)規(guī)范的理解不同,所以在處理某個(gè)設(shè)計(jì)問(wèn)題時(shí),也就會(huì)采取不同的處理方法。對(duì)于鋼筋混凝土框架結(jié)構(gòu)設(shè)計(jì)中,基礎(chǔ)、梁、柱、板四部分應(yīng)注意的問(wèn)題,分別提出了幾點(diǎn)看法。關(guān)鍵詞:結(jié)構(gòu)設(shè)計(jì)基礎(chǔ)梁柱板

      現(xiàn)在越來(lái)越多的建筑物使用鋼筋混凝土結(jié)構(gòu),故鋼筋混凝土結(jié)構(gòu)在整個(gè)建筑市場(chǎng)起到越來(lái)越重要的地位。在鋼筋混凝土結(jié)構(gòu)設(shè)計(jì)中,每個(gè)設(shè)計(jì)者的經(jīng)驗(yàn)不同,對(duì)規(guī)范的理解不同,所以在處理某個(gè)設(shè)計(jì)問(wèn)題時(shí),也就會(huì)采取不同的處理方法。在這十年的結(jié)構(gòu)設(shè)計(jì)工作中,本人也積累了一些經(jīng)驗(yàn),下面就鋼筋混凝土框架結(jié)構(gòu)設(shè)計(jì)中的基礎(chǔ)、梁、柱、板四部分,在設(shè)計(jì)時(shí)應(yīng)注意的問(wèn)題,闡述一下個(gè)人觀點(diǎn)。1.基礎(chǔ)部分

      1.1對(duì)于柱下擴(kuò)展基礎(chǔ)寬度較寬(大于4米)或地基不均勻及地基較軟時(shí)宜采用柱下條基。并應(yīng)考慮節(jié)點(diǎn)處基礎(chǔ)底面積雙向重復(fù)使用的不利因素,適當(dāng)加寬基礎(chǔ)。

      1.2建筑地段較好,基礎(chǔ)埋深大于3米時(shí),應(yīng)建議甲方做地下室。當(dāng)?shù)鼗休d力滿(mǎn)足設(shè)計(jì)要求時(shí),地下室底板可不再外伸以利于防水。每隔30~40米設(shè)一后澆帶,并注明兩個(gè)月后用微膨脹混凝土澆注。設(shè)置地下室可降低地基的附加應(yīng)力,提高地基的承載力(尤其是在周?chē)薪ㄖr(shí)有用),減少地震作用對(duì)上部結(jié)構(gòu)的影響。不應(yīng)設(shè)局部地下室,且地下室應(yīng)有相同的埋深。

      1.3地下室外墻為混凝土?xí)r,相應(yīng)的樓層處梁和基礎(chǔ)梁可取消。1.4抗震縫、伸縮縫在地面以下可不設(shè),連接處應(yīng)加強(qiáng)。但沉降縫兩側(cè)墻體基礎(chǔ)一定要分開(kāi)。

      1.5新建建筑物基礎(chǔ)不宜深于周?chē)延谢A(chǔ)。如深于原有基礎(chǔ),其基礎(chǔ)間的凈距應(yīng)不少于基礎(chǔ)高差的2倍,否則應(yīng)打抗滑移樁,防止原有建筑的破壞。建筑層數(shù)相差較大時(shí),應(yīng)在層數(shù)較低的基礎(chǔ)方格中心的區(qū)域內(nèi)墊焦碴來(lái)調(diào)整基底附加應(yīng)力。

      1.6獨(dú)立基礎(chǔ)偏心不能過(guò)大,必要時(shí)可與相近的基礎(chǔ)做成柱下條基。柱下條形基礎(chǔ)的底板偏心不能過(guò)大,必要時(shí)可作成三面支承一面自由板(類(lèi)似筏基中間開(kāi)

      洞)。兩根柱的柱下條基的荷載重心和基礎(chǔ)底版的形心宜重合,基礎(chǔ)底板可做成梯形或臺(tái)階形,或調(diào)整挑梁兩端的出挑長(zhǎng)度。

      1.7獨(dú)立基礎(chǔ)的拉梁宜通長(zhǎng)配筋,其下應(yīng)墊焦碴。拉梁頂標(biāo)高宜較高,否則底層墻體過(guò)高。

      1.8底層內(nèi)隔墻一般不用做基礎(chǔ),可將地面的混凝土墊層局部加厚。1.9考慮到一般建筑沉降為鍋底形,結(jié)構(gòu)的整體彎曲和上部結(jié)構(gòu)與基礎(chǔ)的協(xié)同作用,頂、底板鋼筋應(yīng)拉通(多層的負(fù)筋可截?cái)?/2或1/3),且縱向基礎(chǔ)梁的底筋也應(yīng)拉通。

      1.10基礎(chǔ)底板混凝土不宜大于C3O,一是沒(méi)用,二是容易出現(xiàn)裂縫。1.11基礎(chǔ)底面積不應(yīng)因地震附加力而過(guò)分加大,否則地震下安全了而常規(guī)情況下反而沉降差異較大,本末倒置。免費(fèi)論文下載中心 2.柱部分

      2.1地上為圓柱時(shí),地下部分應(yīng)改為方柱,方便施工。圓柱縱筋根數(shù)最少為8根,箍筋用螺旋箍,并注明端部應(yīng)有一圈半的水平段。方柱箍筋應(yīng)使用井字箍,并按規(guī)范加密。角柱、樓梯間柱應(yīng)增大縱筋并全柱高加密箍筋。幼兒園不宜用方柱。2.2原則上柱的縱筋宜大直徑大間距,但間距不宜大于200。

      2.3柱內(nèi)埋管,由于梁的縱筋錨入柱內(nèi),一般情況下僅在柱的四角才有條件埋設(shè)較粗的管。管截面面積占柱截面4%以下時(shí),可不必驗(yàn)算。柱內(nèi)不得穿暖氣管。2.4柱斷面不宜小于450×450,混凝土不宜小于C25,否則梁縱筋錨入柱內(nèi)的水平段不容易滿(mǎn)足0.45La的要求,不滿(mǎn)足時(shí)應(yīng)加橫筋;否則在梁柱節(jié)點(diǎn)處鋼筋太密,混凝土澆筑困難。異型柱結(jié)構(gòu),梁縱筋一排根數(shù)不宜過(guò)多,柱端部縱筋不宜過(guò)密,否則節(jié)點(diǎn)混凝土澆筑困難。當(dāng)有部分矩形柱部分異型柱時(shí),應(yīng)注意異型柱的剛度要和矩形柱相接近,不要相差太大。

      2.5柱應(yīng)盡量采用高強(qiáng)度混凝土來(lái)滿(mǎn)足軸壓比的限制,減小斷面尺寸。2.6盡量避免短柱,短柱箍筋應(yīng)全高加密,短柱縱筋不宜過(guò)大。2.7考慮到豎向地震作用,柱子的軸壓比及配筋宜留有余地。

      2.8獨(dú)立柱上或柱的中部(半層處)有挑梁時(shí),挑梁長(zhǎng)度應(yīng)有限制。3.梁部分

      3.1梁上有次梁處(包括挑梁端部)應(yīng)附加箍筋和吊筋,宜優(yōu)先采用附加箍筋。附加筋一般要有,但不應(yīng)絕對(duì)。規(guī)范說(shuō)的清楚,位于梁下部或梁截面高度范圍內(nèi)的集中荷載,應(yīng)全部由附加橫向鋼筋承擔(dān)。也就是說(shuō),位于梁上的集中力如梁上柱、梁上后做的梁如水箱下的墊梁不必加附加筋。位于梁下部的集中力應(yīng)加附加筋。但梁截面高度范圍內(nèi)的集中荷載可根據(jù)具體情況而定。當(dāng)主次梁截面相差不大,次梁荷載較大時(shí),應(yīng)加附加筋。當(dāng)主梁高度很高,次梁截面很小、荷載很小時(shí),如快接近板上附加暗梁,主梁可不加附加筋。還有當(dāng)主次梁截面均很大,如工藝要求形成的主次深梁,而荷載相對(duì)不大,主梁也可不加附加筋。

      3.2當(dāng)外部梁跨度相差不大時(shí),梁高宜等高,尤其是外部的框架梁。當(dāng)梁底距外窗頂尺寸較小時(shí),宜加大梁高做至窗頂。外部框架梁盡量做成外皮與柱外皮平齊。梁也可偏出柱邊一較小尺寸。梁與柱的偏心可大于1/4柱寬,并宜小于1/3柱寬。

      3.3梁上有次梁時(shí),應(yīng)避免次梁搭接在主梁的支座附近,否則應(yīng)考慮由次梁引起的主梁抗扭,或增加構(gòu)造抗扭縱筋和箍筋。當(dāng)采用現(xiàn)澆板時(shí),抗扭問(wèn)題并不嚴(yán)重。

      3.4原則上梁縱筋宜小直徑小間距,有利于抗裂,但應(yīng)注意鋼筋間距要滿(mǎn)足要求,并與梁的斷面相應(yīng)。箍筋按規(guī)定在梁端頭加密。布筋時(shí)應(yīng)將縱筋等距,箍筋肢距可不等。小斷面的連續(xù)梁或框架梁,上、下縱筋均應(yīng)采用同直徑的,盡量不在支座搭接。

      3.5端部與框架梁相交或彈性支承在墻體上的次梁,梁端支座可按簡(jiǎn)支考慮,但梁端箍筋應(yīng)加密。

      3.6上反梁的板吊在梁底下,板荷載宜由箍筋承受,或適當(dāng)增大箍筋。梁支承偏心布置的墻時(shí)宜做下挑沿。

      3.7挑梁宜作成等截面(大挑梁外露者除外)。與挑板不同,挑梁的自重占總荷載的比例很小,作成變截面不能有效減輕自重。變截面挑梁的箍筋,每個(gè)都不一樣,難以施工。變截面梁的撓度也大于等截面梁。挑梁端部有次梁時(shí),注意要附加箍筋或吊筋。一般挑梁根部不必附加斜筋,除非受剪承載力不足。對(duì)于大挑梁,梁的下部宜配置受壓鋼筋以減小撓度。挑梁配筋應(yīng)留有余地。免費(fèi)論文下載中心

      3.8梁上開(kāi)洞時(shí),不但要計(jì)算洞口加筋,更應(yīng)驗(yàn)算梁洞口下偏拉部分的裂縫寬度。梁從構(gòu)造上能保證不發(fā)生沖切破壞和斜截面受彎破壞。

      3.9挑梁出挑長(zhǎng)度小于梁高時(shí),應(yīng)按牛腿計(jì)算或按深梁構(gòu)造配筋。

      3.10扁梁寬度不必過(guò)大,只要鋼筋能正常擺下及受剪滿(mǎn)足即可。因?yàn)樵趽隙扔?jì)算時(shí),梁寬對(duì)剛度影響不大,加寬一倍,撓度減小20%左右。相對(duì)來(lái)講,增大鋼筋更經(jīng)濟(jì),鋼筋加大一倍,撓度減小60%左右,同時(shí)梁的上筋應(yīng)大部分通長(zhǎng)布置,以減小混凝土徐變對(duì)撓度的增大,如果上筋不小于下筋,撓度減小20%。3.11當(dāng)一寬框架梁托兩排間距較小的柱時(shí),可加一剛性挑梁,兩個(gè)柱支承在剛性挑梁的端頭。

      3.12梁寬大于350時(shí),應(yīng)采用四肢箍。4.現(xiàn)澆板部分

      4.1板的鋼筋宜采用大直徑大間距,但間距不大于200,間距盡量用200。(一般跨度小于6.6米的板的裂縫均可滿(mǎn)足要求)。板上下鋼筋間距宜相等,直徑可不同,但鋼筋直徑類(lèi)型也不宜過(guò)多。

      4.2相連幾個(gè)房間的同型號(hào)同間距板底鋼筋宜連通。

      4.3配筋計(jì)算時(shí),可考慮塑性?xún)?nèi)力重分布,將板上筋乘以0.8~0.9的折減系數(shù),將板下筋乘以1.1~1.2的放大系數(shù)。

      ——出處:《中國(guó)經(jīng)濟(jì)與管理科學(xué)》2009年第7期

      Structure design of reinforced concrete frame

      Zhang Yongtao Ji Guangdong(Shandong Province Metallurgical Design Institute Co., Ltd.Laiwu 271104)

      Abstract: In the reinforced concrete structure design, each designer's experience is different, different understanding of norms, so in dealing with a certain design issues, it would take a different approach.For the design of reinforced concrete frame structure, foundations, beams, columns, boards should pay attention to the issue of four parts, respectively, made a few observations.Keywords: Structural design of foundation beam plate More and more buildings to use reinforced concrete structure, reinforced concrete structure and therefore the entire construction market play an increasingly important role.In the reinforced concrete structural design, each designer's experience is different, different understanding of norms, so in dealing with a certain design issues, it would take a different approach.In this decade, the structural design work, I have accumulated some experience, the following on the design of reinforced concrete frame structure, the foundation, beams, columns, panels of four parts in the design should pay attention to the problem, elaborate personal views.1.The fundamental elements of The expansion of the basis for the column width under a wide(greater than 4 meters)or the uneven ground and foundation should be adopted when compared with the soft base of the next column.And should consider the basis of node size at the end of a two-way repeated use of unfavorable factors, appropriate widening base.1.2 Building lot better basis for depth greater than 3 meters, should recommend to the Party to do the basement.Bearing capacity of the local base to meet the design requirements, the basement floor can be no overhang to facilitate water.Every 30 ~ 40 meters is located one after the pouring

      zone, and indicate the two months after the pouring of concrete with micro-expansion.Setting the foundation of the basement can reduce the additional stress, improve the bearing capacity of foundations(especially in the construction around when useful)to reduce the role of the upper structure of the earthquake impact.Should not be any partial basement, and the basement should have the same depth.1.3 for the concrete basement wall, the corresponding floor beams and foundation beams at cancel.1.4 earthquake seam, expansion joints on the ground below may from time to set up, connections should be strengthened.However, the basis of settlement joint on both sides of the wall must be separated.The basis of 1.5 new buildings should not be darker than the surrounding existing basis.As deeply as the original foundation, based on the basis of inter-spacing of not less than 2 times the height difference, or to fight anti-sliding pile should be to prevent the destruction of the original building.Larger difference between the construction layers should be the basis of the lower layers within the region grid center ballast to adjust the base pad coke additional stress.1.6 Independence-based bias can not be too large, if necessary, the foundation made with similar articles under column base.Column strip foundation under the floor can not be too eccentric, if necessary, could be made on three sides, supporting one side of free(similar to the Raft-based intermediate open hole).Column 2 column article under the base load center of gravity and centroid-based bottom plate should overlap the foundation floor or stairs can be made into trapezoidal shape, or adjusting the length of cantilever beam at both ends of Chutiao.1.7 Independence-based pull-Liang Yi-length reinforcement, under which should focus ballast mat.Top elevation should pull high beam, or the bottom of the wall is too high.1.8 in the bottom wall generally do not have to do based on the concrete floor cushion can be partially thickened.1.9 Taking into account the general settlement of the bottom of the pot-shaped building, the structure of the overall bending and the upper structure and the basis of synergies, top and bottom reinforcement should be raton(multi-layer of negative reinforcement can be cut off 1 / 2 or 1 / 3), and the foundation beam bottom longitudinal reinforcement should also be raton.1.10 foundation slab of concrete should not be larger than C3O, one useless the second is prone to cracks.1.11 The foundation area should not unduly increase the earthquake additional force, otherwise the next earthquake safety, rather the contrary, the settlement, under normal circumstances are quite different cart before the horse.Reposted elsewhere in the paper for free download 2.Column part of the 2.1 on the ground for the cylinder, the underground portion should be replaced by square columns, to facilitate construction.Column longitudinal reinforcement root number at least 8, stirrup with spiral bands, and indicate the end of the horizontal segment should have a lap and a half.Square columns Tic-Tac-hoop stirrups should be used, in accordance with standard encryption.Corner column, stair column longitudinal reinforcement should be increased, and the whole column stirrups high encryption.Kindergarten should not use the square column.2.2 In principle, the vertical column reinforcement should large-diameter large spacing, but the pitch should not be larger than 200.2.3 Column pipe, due to the beam longitudinal reinforcement anchored into the column, the general only in the column under the conditions laid four corners have thick tube.Tube-sectional area of column cross section accounted for less than 4%, it can not checking.Column shall not clothing

      trachea.2.4 column cross-section should not be less than 450 ??450, concrete should not be less than the C25, otherwise the beam longitudinal reinforcement anchored into the column level within the segment is not easy to satisfy the requirements of 0.45La, does not meet the horizontal bars should be added;otherwise reinforced beam-column nodes are too dense, concrete placement difficult.Special-shaped column structure, and beam longitudinal reinforcement should not be too much root number in a row and column longitudinal reinforcement ends should not be too dense, otherwise the node concrete placement difficult.When there is some part of the rectangular column-shaped columns, they should pay attention to special-shaped columns and rectangular column stiffness was similar and not that much difference.2.5 column should be using high-strength concrete to meet the axial load ratio limits, reduce the section size.2.6 try to avoid short columns, short columns stirrup should be full of high encryption, short column longitudinal reinforcement should not be too large.2.7 Taking into account the role of vertical earthquake, columns under axial compression ratio and reinforcement should leave some leeway.2.8 independent of the central column or columns(semi-floor office)are cantilever beam, the cantilever beam length should be limited.3.LIANG part of the 3.1 beam with sub-beam Department(including the cantilever beam ends)should be attached stirrups and hanging bars, should give priority to adopt additional stirrups.Additional tendons in general should be, but not absolute.A clear specification that is located in the lower beam or high beam within the scope of the concentrated load shall be borne entirely by additional transverse reinforcement.In other words, the concentration of power in the beam, such as beam columns, beams after the beam to do under

      the pad-like water tanks do not have to add additional muscle.Is located in the lower beam of concentration should be added additional reinforcement.However, a high beam within the concentrated load can be determined according to specific circumstances.When the primary and secondary beam cross-section more or less, sub-beam load is large, additional reinforcement should be added.When the main beam at very high altitudes, sub-beam cross-section is very small, load is very small, such as the approach the board added the dark beam, main beam may from time to add additional muscle.There were significant when the primary and secondary beam, such as the process requires the formation of the primary and secondary deep beam, while the load is relatively small, the main beam or not to add additional muscle.3.2 when the external beam span or less, Liang Gao Yi high, especially outside the frame beam.When the beam away from the outer windows of the top end of small size, it is desirable to do to increase the beam window of a high top.As far as possible outside the framework of beams and columns made of skin skin flush.Liang-chu, may also be missed while a smaller size.Eccentric beam-column may be greater than 1 / 4 columns wide and appropriate less than 1 / 3 of column width.There are times when the beam 3.3 beam should avoid secondary beam overlap in the vicinity of the main beam of the bearing, otherwise, consideration should be given by the second torsion beam caused by the main beam, or increasing the longitudinal reinforcement and stirrup torsional structure.When using in-situ plate, the torsion problem is not serious.3.4 In principle, small-diameter beam longitudinal reinforcement should a small spacing is conducive to cracking, but it should be noted that reinforcement spacing to meet the requirements, and with the corresponding cross-section of beam.Stirrups at the end of the beam according to the provisions of the first encryption.Fabric reinforcement should be

      equidistant longitudinal reinforcement, stirrups, etc.from time away from the limb.Small cross-section of a continuous beam or frame beams, the upper and lower longitudinal reinforcement should be using the same diameter as much as possible not to overlap bearings.3.5 end with the frame beams intersect, or elastic support at the wall on the sub-beams, simply supported beam end bearing may be considered, but the end of the beam stirrups should be encrypted.3.6 The panel of anti-beam suspended beneath the beam, plate load appropriate for the stirrups to bear, or an appropriate increase in stirrup.Eccentric arrangement of beams supporting the walls along the opportune time to do the next pick.3.7 pick Liang Yiross-section(large cantilever beam except those exposed).And pick a different panel to pick the beam weight ratio of the total load is small, ariable cross-section can not effectively reduce weight.Variable cross-section cantilever beam of the stirrups, each is different and difficult construction.Variable cross-section beam deflection is also greater than the other beam.Cantilever beam with secondary beam end, attention should be attached stirrups or hanging bars.Generally do not have to add the root of cantilever beam oblique muscle, unless the lack of shear strength.For large cantilever beam, the beam bottom reinforcement should configure the compression to reduce the deflection.Cantilever beam reinforcement should leave room for the.Reposted elsewhere in the paper for free download 3.8 beam openings, not only to calculate the hole reinforcement, hole should be checking under the partial pull-beam part of the crack width.Beams from the structure does not occur on the punching can guarantee the damage and oblique cross-section flexural damage.3.9 Chutiao cantilever beam is less than the length of beam is high, should be calculated or bracket structure reinforced by deep beams.3.10 flat-beam width not too large, as long as the steel can be placed

      under the normal and shear can be met.Because the deflection calculation, the beam width on the stiffness had little impact broadening doubled, the deflection reduced about 20%.Relatively speaking, increasing the steel more economical, steel increased to double the deflection reduced about 60%, while the majority of the beam on the tendon to be a long-pass arrangement to reduce the deflection of concrete creep on the increase, if the tendon not less than under the ribs, deflection reduced by 20%.3.11 As a broad framework of the Beam smaller distance between two rows of columns, it can add a stiff cantilever beam, the two columns supported on rigid cantilever beam of the end of the first.3.12 beam large at the 350 should be used limbs hoop.4.Part Slab 4.1 The board should adopt the large-diameter steel big pitch, but the spacing is not greater than 200, the pitch as far as possible with the 200.(Usually span of less than 6.6 meters cracks in the board can meet requirements).Under the steel plate spacing should equal diameter can be different, but the bar diameter type is also not too much.4.2 connected to a few rooms at the end of the same model reinforced with the pitch plate should connect.4.3 reinforcement calculations, may consider plastic redistribution of internal force will be multiplied by 0.8 to 0.9 bars on-board the discount factor will be multiplied by the plate under the tendons of the amplification factor of 1.1 ~ 1.2.——From: Chinese Economy Management Science Magazine,2009.7

      第四篇:框架結(jié)構(gòu)設(shè)計(jì)技術(shù)

      框架結(jié)構(gòu)設(shè)計(jì)技術(shù)

      摘要: 在不同類(lèi)型的結(jié)構(gòu)設(shè)計(jì)中有些內(nèi)容是一樣的,如樓板、樓梯等,寫(xiě)此文的用意是幫助設(shè)計(jì)者在做框架結(jié)構(gòu)設(shè)計(jì)時(shí)參見(jiàn)本文可減少漏項(xiàng)、減少差錯(cuò)等,與上篇內(nèi)容相同的讀者可略過(guò)。

      具體內(nèi)容如下:

      一.結(jié)構(gòu)設(shè)計(jì)說(shuō)明

      主要是設(shè)計(jì)依據(jù),抗震等級(jí),人防等級(jí),地基情況及承載力,防潮抗?jié)B做法,活荷載值,材料等級(jí),施工中的注意事項(xiàng),選用詳圖,通用詳圖或節(jié)點(diǎn),以及在施工圖中未畫(huà)出而通過(guò)說(shuō)明來(lái)表達(dá)的信息。如混凝土的含堿量不得超過(guò)3kg/m3等等。

      二.各層的結(jié)構(gòu)布置圖,包括:

      (1).預(yù)制板的布置(板的選用、板縫尺寸及配筋)。

      標(biāo)注預(yù)制板的塊數(shù)和類(lèi)型時(shí), 不要采用對(duì)角線(xiàn)的形式。因?yàn)榇朔N方法易造成線(xiàn)的交叉, 宜采用水平線(xiàn)或垂直線(xiàn)的方法, 相同類(lèi)型的房間直接標(biāo)房間類(lèi)型號(hào)。應(yīng)全樓統(tǒng)一編號(hào),可減少設(shè)計(jì)工作量,也方便施工人員看圖。板縫盡量為40, 此種板縫可不配筋或加一根筋。布板時(shí)從房間里面往外布板, 盡量采用寬板, 現(xiàn)澆板帶留在靠窗處, 現(xiàn)澆板帶寬最好≥200(考慮水暖的立管穿板)。

      如果構(gòu)造上要求有整澆層時(shí), 板縫應(yīng)大于60。整澆層厚50, 配雙向φ6@250, 混凝土C20。純框架結(jié)構(gòu)一般不需要加整澆層。構(gòu)造柱處不得布預(yù)制板。地下車(chē)庫(kù)由于防火要求不可用預(yù)制板??蚣芙Y(jié)構(gòu)不宜使用長(zhǎng)向板,否則長(zhǎng)向板與框架梁平行相接處易出現(xiàn)裂縫。建議使用PMCAD的人工布板功能布預(yù)制板,自動(dòng)布板可能不能滿(mǎn)足用戶(hù)的施工圖要求,僅能滿(mǎn)足定義荷載傳遞路線(xiàn)的要求。對(duì)樓層凈高很敏感、跨度超過(guò)6.9米或不符合模數(shù)時(shí)可采用SP板,SP板120厚可做到7.2米跨。

      (2).現(xiàn)澆板的配筋(板上、下鋼筋,板厚尺寸)。

      板厚一般取120、140、160、180四種尺寸或120、150、180三種尺寸。盡量用二級(jí)鋼包括直徑φ10(目前供貨較少)的二級(jí)鋼,直徑≥12的受力鋼筋,除吊鉤外,不得采用一級(jí)鋼。鋼筋宜大直徑大間距,但間距不大于200,間距盡量用200。(一般跨度小于6.6米的板的裂縫均可滿(mǎn)足要求)??缍刃∮?米的板上部鋼筋不必?cái)嚅_(kāi),鋼筋也可不畫(huà),僅說(shuō)明鋼筋為雙向雙排φ8@200。板上下鋼筋間距宜相等,直徑可不同,但鋼筋直徑類(lèi)型也不宜過(guò)多。頂層及考慮抗裂時(shí)板上筋可不斷,或50%連通,較大處附加鋼筋,拉通筋均應(yīng)按受拉搭接鋼筋。板配筋相同時(shí),僅標(biāo)出板號(hào)即可。

      一般可將板的下部筋相同和部分上部筋相同的板編為一個(gè)板號(hào),將不相同的上部筋畫(huà)在圖上。當(dāng)板的形狀不同但配筋相同時(shí)也可編為一個(gè)板號(hào)。應(yīng)全樓統(tǒng)一編號(hào)。當(dāng)考慮穿電線(xiàn)管時(shí),板厚≥120,不采用薄板加墊層的做法。電的管井電線(xiàn)引出處的板,因電線(xiàn)管過(guò)多有可

      能要加大板厚至180(考慮四層32的鋼管疊加)。宜盡量用大跨度板,不在房間內(nèi)(尤其是住宅)加次梁。說(shuō)明分布筋為φ6@250,溫度影響較大處可為φ8@200。板頂標(biāo)高不同時(shí),板的上筋應(yīng)分開(kāi)或傾斜通過(guò)?,F(xiàn)澆挑板陽(yáng)角加輻射狀附加筋(包括內(nèi)墻上的陽(yáng)角)。現(xiàn)澆挑板陰角的板下宜加斜筋。頂層應(yīng)建議甲方采用現(xiàn)澆樓板,以利防水,并加強(qiáng)結(jié)構(gòu)的整體性及方便裝飾性挑沿的穩(wěn)定。外露的挑沿、雨罩、挑廊應(yīng)每隔10~15米設(shè)一10mm的縫,鋼筋不斷。盡量采用現(xiàn)澆板,不采用予制板加整澆層方案。衛(wèi)生間做法可為70厚+10高差(取消墊層)。8米以下的板均可以采用非預(yù)應(yīng)力板。

      L、T或十字形建筑平面的陰角處附近的板應(yīng)現(xiàn)澆并加厚,雙向雙排配筋,并附加45度的4根16的抗拉筋?,F(xiàn)澆板的配筋建議采用PMCAD軟件自動(dòng)生成,一可加快速度,二來(lái)盡量減小筆誤。自動(dòng)生成樓板配筋時(shí)建議不對(duì)鋼筋編號(hào),因工程較大時(shí)可能編出上百個(gè)鋼筋號(hào),查找困難,如果要編號(hào),編號(hào)不應(yīng)出房間。配筋計(jì)算時(shí),可考慮塑性?xún)?nèi)力重分布,將板上筋乘以0.8~0.9的折減系數(shù),將板下筋乘以1.1~1.2的放大系數(shù)。值得注意的是,按彈性計(jì)算的雙向板鋼筋是板某幾處的最大值,按此配筋是偏于保守的,不必再人為放大。支承在外圈框架梁上的板負(fù)筋不宜過(guò)大,否則將對(duì)梁產(chǎn)生過(guò)大的附加扭距。一般:板厚>150時(shí)采用φ10@200;否則用φ8@200。

      PMCAD生成的板配筋圖應(yīng)注意以下幾點(diǎn):1.單向板是按塑性計(jì)算的,而雙向板按彈性計(jì)算,宜改成一種計(jì)算方法。2.當(dāng)厚板與薄板相接時(shí),薄板支座按固定端考慮是適當(dāng)?shù)模癜寰筒缓线m,宜減小厚板支座配筋,增大跨中配筋。3.非矩形板宜減小支座配筋,增大跨中配筋。4.房間邊數(shù)過(guò)多或凹形板應(yīng)采用有限元程序驗(yàn)算其配筋。PMCAD生成的板配筋圖為PM?.T。

      板一般可按塑性計(jì)算,尤其是基礎(chǔ)底板和人防結(jié)構(gòu)。但結(jié)構(gòu)自防水、不允許出現(xiàn)裂縫和對(duì)防水要求嚴(yán)格的建筑, 如坡、平屋頂、櫥廁、配電間等應(yīng)采用彈性計(jì)算。室內(nèi)輕隔墻下一般不應(yīng)加粗鋼筋,一是輕隔墻有可能移位,二是板整體受力,應(yīng)整體提高板的配筋。只有垂直單向板長(zhǎng)邊的不可能移位的隔墻,如廁所與其他房間的隔墻下才可以加粗鋼筋。坡屋頂板為偏拉構(gòu)件,應(yīng)雙向雙排配筋。

      (3).關(guān)于過(guò)梁布置及輕隔墻。

      現(xiàn)在框架填充墻一般為輕墻,過(guò)梁一般不采用預(yù)制混凝土過(guò)梁,而是現(xiàn)澆梁帶。應(yīng)注明采用的輕墻的做法及圖集,如北京地區(qū)的京94SJ19,并注明過(guò)梁的補(bǔ)充筋。當(dāng)過(guò)梁與柱或構(gòu)造柱相接時(shí),柱應(yīng)甩筋,過(guò)梁現(xiàn)澆。不建議采用加氣混凝土做圍護(hù)墻,裝修難做并不能用在廁所處。

      (4).雨蓬、陽(yáng)臺(tái)、挑檐布置和其剖面詳圖。

      注意:雨棚和陽(yáng)臺(tái)的豎板現(xiàn)澆時(shí),最小厚度應(yīng)為80,否則難以施工。豎筋應(yīng)放在板中部。當(dāng)做雙排筋時(shí),高度<900,最小板厚100;高度>900時(shí),最小板厚120。陽(yáng)臺(tái)的豎板應(yīng)盡量現(xiàn)澆,預(yù)制擋板的相交處極易裂縫。雨棚和陽(yáng)臺(tái)上有斜的裝飾板時(shí),板的鋼筋放斜板的上面,并通過(guò)水平挑板的下部錨入墻體圈梁(即挑板雙層布筋)。兩側(cè)的封板可采用泰柏板封堵,鋼筋與泰柏板的鋼絲焊接,不必采用混凝土結(jié)構(gòu)。挑板挑出長(zhǎng)度大于2米時(shí)宜配置板下

      構(gòu)造筋,較長(zhǎng)外露挑板(包括豎板)宜配溫度筋。挑板內(nèi)跨板上筋長(zhǎng)度應(yīng)大于等于挑板出挑長(zhǎng)度,尤其是挑板端部有集中荷載時(shí)。

      內(nèi)挑板端部宜加小豎沿,防止清掃時(shí)灰塵落下。當(dāng)頂層陽(yáng)臺(tái)的雨搭為無(wú)組織排水時(shí),雨搭出挑長(zhǎng)度應(yīng)大于其下陽(yáng)臺(tái)出挑長(zhǎng)度100,頂層陽(yáng)臺(tái)必須設(shè)雨搭。挑板配筋應(yīng)有余地,并應(yīng)采用大直徑大間距鋼筋,給工人以下腳的地方,防止踩彎。挑板內(nèi)跨板跨度較小,跨中可能出現(xiàn)負(fù)彎距,應(yīng)將挑板支座的負(fù)筋伸過(guò)全跨。挑板端部板上筋通常兜一圈向上,但當(dāng)鋼筋直徑大于等于12時(shí)是難以施工的,應(yīng)另加筋。

      (5).樓梯布置。采用X型斜線(xiàn)表示樓梯間,并注明樓梯間另詳。盡量用板式樓梯,方便設(shè)計(jì)及施工,也較美觀。

      (6).板頂標(biāo)高。可在圖名下說(shuō)明大多數(shù)的板厚及板頂標(biāo)高,廚廁及其它特殊處在其房間上另外標(biāo)明。

      (7).梁布置及其編號(hào),應(yīng)按層編號(hào),如L-1-XX,1指1層,XX為梁的編號(hào)。柱布置及編號(hào)。

      (8).板上開(kāi)洞(廚、廁、電氣及設(shè)備)洞口尺寸及其附加筋,附加筋不必一定錨入板支座,從洞邊錨入La即可。板上開(kāi)洞的附加筋,如果洞口處板僅有正彎距,可只在板下加筋;否則應(yīng)在板上下均加附加筋。留筋后澆的板宜用虛線(xiàn)表示其范圍,并注明用提高一級(jí)的膨脹混凝土澆筑。未澆筑前應(yīng)采取有效支承措施。住宅躍層樓梯在樓板上所開(kāi)大洞,周邊不宜加梁,應(yīng)采用有限元程序計(jì)算板的內(nèi)力和配筋。板適當(dāng)加厚, 洞邊加暗梁。

      (9).屋面上人孔、通氣孔位置及詳圖。

      (10).在平面圖上不能表達(dá)清楚的細(xì)節(jié)要加剖面,可在建筑墻體剖面做法的基礎(chǔ)上,對(duì)應(yīng)畫(huà)結(jié)構(gòu)詳圖。

      三.基礎(chǔ)平面圖及詳圖:

      (1).在柱下擴(kuò)展基礎(chǔ)寬度較寬(大于4米)或地基不均勻及地基較軟時(shí)宜采用柱下條基。并應(yīng)考慮節(jié)點(diǎn)處基礎(chǔ)底面積雙向重復(fù)使用的不利因素,適當(dāng)加寬基礎(chǔ)。

      (2).當(dāng)基礎(chǔ)下有防空洞或枯井等時(shí),可做一大厚板將其跨過(guò)。

      (3).混凝土基礎(chǔ)下應(yīng)做墊層。當(dāng)有防水層時(shí),應(yīng)考慮防水層厚度。

      (4).建筑地段較好,基礎(chǔ)埋深大于3米時(shí),應(yīng)建議甲方做地下室。地下室底板,當(dāng)?shù)鼗休d力滿(mǎn)足設(shè)計(jì)要求時(shí),可不再外伸以利于防水。每隔30~40米設(shè)一后澆帶,并注明兩個(gè)月后用微膨脹混凝土澆注。設(shè)置地下室可降低地基的附加應(yīng)力,提高地基的承載力(尤其是在周?chē)薪ㄖr(shí)有用),減少地震作用對(duì)上部結(jié)構(gòu)的影響。不應(yīng)設(shè)局部地下室,且地下室應(yīng)

      有相同的埋深??稍诜ぐ鍏^(qū)格中間挖空墊聚苯來(lái)調(diào)整高低層的不均勻沉降。

      (5).地下室外墻為混凝土?xí)r,相應(yīng)的樓層處梁和基礎(chǔ)梁可取消。

      (6).抗震縫、伸縮縫在地面以下可不設(shè)縫,連接處應(yīng)加強(qiáng)。但沉降縫兩側(cè)墻體基礎(chǔ)一定要分開(kāi)。

      (7).新建建筑物基礎(chǔ)不宜深于周?chē)延谢A(chǔ)。如深于原有基礎(chǔ),其基礎(chǔ)間的凈距應(yīng)不少于基礎(chǔ)之間的高差的1.5至2倍,否則應(yīng)打抗滑移樁,防止原有建筑的破壞。建筑層數(shù)相差較大時(shí),應(yīng)在層數(shù)較低的基礎(chǔ)方格中心的區(qū)域內(nèi)墊焦碴來(lái)調(diào)整基底附加應(yīng)力。

      (8).獨(dú)立基礎(chǔ)偏心不能過(guò)大,必要時(shí)可與相近的柱做成柱下條基。柱下條形基礎(chǔ)的底板偏心不能過(guò)大,必要時(shí)可作成三面支承一面自由板(類(lèi)似筏基中間開(kāi)洞)。兩根柱的柱下條基的荷載重心和基礎(chǔ)底版的形心宜重合,基礎(chǔ)底板可做成梯形或臺(tái)階形,或調(diào)整挑梁兩端的出挑長(zhǎng)度。

      (9).采用獨(dú)立柱基時(shí),獨(dú)立基礎(chǔ)受彎配筋不必滿(mǎn)足最小配筋率要求,除非此基礎(chǔ)非常重要,但配筋也不得過(guò)小。獨(dú)立基礎(chǔ)是介于鋼筋混凝土和素混凝土之間的結(jié)構(gòu)。面積不大的獨(dú)立基礎(chǔ)宜采用錐型基礎(chǔ),方便施工。

      (10).獨(dú)立基礎(chǔ)的拉梁宜通長(zhǎng)配筋,其下應(yīng)墊焦碴。拉梁頂標(biāo)高宜較高,否則底層墻體過(guò)高。

      (11).底層內(nèi)隔墻一般不用做基礎(chǔ),可將地面的混凝土墊層局部加厚。

      (12).考慮到一般建筑沉降為鍋底形、結(jié)構(gòu)的整體彎曲和上部結(jié)構(gòu)和基礎(chǔ)的協(xié)同作用,頂、底板鋼筋應(yīng)拉通(多層的負(fù)筋可截?cái)?/2或1/3),且縱向基礎(chǔ)梁的底筋也應(yīng)拉通。

      (13).基礎(chǔ)平面圖上應(yīng)加指北針。

      (14).基礎(chǔ)底板混凝土不宜大于C30,一是沒(méi)用,二是容易出現(xiàn)裂縫。

      (15).可用JCCAD軟件自動(dòng)生成基礎(chǔ)布置和基礎(chǔ)詳圖。生成的基礎(chǔ)平面圖名為JCPM.T,生成的基礎(chǔ)詳圖名為JCXT?.T。

      (16).基礎(chǔ)底面積不應(yīng)因地震附加力而過(guò)分加大,否則地震下安全了而常規(guī)情況下反而沉降差異較大,本末倒置。

      請(qǐng)參照《建筑地基基礎(chǔ)設(shè)計(jì)規(guī)范GBJ7-89》和各地方的地基基礎(chǔ)規(guī)程。

      四.暖溝圖及基礎(chǔ)留洞圖:

      (1).溝蓋板在遇到電線(xiàn)管時(shí)下降(500),室外暖溝上一般有400厚的覆土。

      (2).注明暖溝兩側(cè)墻體的厚度及材料作法。暖溝較深時(shí)應(yīng)驗(yàn)算強(qiáng)度。

      (3).洞口大于400時(shí)應(yīng)加過(guò)梁,暖溝應(yīng)加通氣孔。

      (4).基礎(chǔ)埋深較淺時(shí)暖溝入口底及基礎(chǔ)留洞有可能比基礎(chǔ)還低,此時(shí)基礎(chǔ)應(yīng)局部降低。

      (5).濕陷性黃土地區(qū)或膨脹土地區(qū)暖溝做法不同于一般地區(qū)。應(yīng)按濕陷性黃土地區(qū)或膨脹土地區(qū)的特殊要求設(shè)計(jì)。

      (6).暖溝一般做成1200寬,1000的在維修時(shí)偏小。

      五.樓梯詳圖:

      (1).應(yīng)注意:梯梁至下面的梯板高度是否夠,以免碰頭,尤其是建筑入口處。

      (2).梯段高度高差不宜大于20,以免易摔跤

      (3).兩倍的梯段高度加梯段長(zhǎng)度約等于600。幼兒園樓梯踏步宜120高。

      (4).樓梯折板、折梁陰角在下時(shí)縱筋應(yīng)斷開(kāi),并錨入受壓區(qū)內(nèi)La,折梁還應(yīng)加附加箍筋

      (5).樓梯的建筑做法一般與樓面做法不同,注意樓梯板標(biāo)高與樓面板的銜接。

      (6).樓梯梯段板計(jì)算方法:當(dāng)休息平臺(tái)板厚為80~100,梯段板厚100~130,梯段板跨度小于4米時(shí),應(yīng)采用1/10的計(jì)算系數(shù),并上下配筋相同;當(dāng)休息平臺(tái)板厚為80~100,梯段板厚160~200,梯段板跨度約6米左右時(shí),應(yīng)采用1/8的計(jì)算系數(shù),板上配筋可取跨中的1/3~1/4,并且不得過(guò)大。此兩種計(jì)算方法是偏于保守的。任何時(shí)候休息平臺(tái)與梯段板平行方向的上筋均應(yīng)拉通,并應(yīng)與梯段板的配筋相應(yīng)。梯段板板厚一般取1/25~1/30跨度。

      (7).注意當(dāng)板式樓梯跨度大于5米時(shí),撓度不容易滿(mǎn)足。應(yīng)注明加大反拱或增大配筋。

      (8).當(dāng)休息平臺(tái)板為懸挑板時(shí),其內(nèi)部的樓梯梯段板負(fù)筋應(yīng)大于休息平臺(tái)板的板上筋,長(zhǎng)度也應(yīng)大于平臺(tái)板筋。

      (9).樓層處的休息平臺(tái)板的配筋應(yīng)與樓層板統(tǒng)一考慮配筋,主要是板的負(fù)筋。

      六.梁詳圖:

      (1).梁上有次梁處(包括挑梁端部)應(yīng)附加箍筋和吊筋,宜優(yōu)先采用附加箍筋。梁上小柱和水箱下, 架在板上的梁, 不必加附加筋??稍诮Y(jié)構(gòu)設(shè)計(jì)總說(shuō)明處畫(huà)一節(jié)點(diǎn),有次梁處兩側(cè)各加三根主梁箍筋,荷載較大處詳施工圖。

      (2).當(dāng)外部梁跨度相差不大時(shí),梁高宜等高,尤其是外部的框架梁。當(dāng)梁底距外窗頂尺寸較小時(shí),宜加大梁高做至窗頂。外部框架梁盡量做成外皮與柱外皮齊平。梁也可偏出柱邊

      一較小尺寸。梁與柱的偏心可大于1/4柱寬,并宜小于1/3柱寬。

      (3).折梁陰角在下時(shí)縱筋應(yīng)斷開(kāi),并錨入受壓區(qū)內(nèi)La,還應(yīng)加附加箍筋

      (4).梁上有次梁時(shí),應(yīng)避免次梁搭接在主梁的支座附近,否則應(yīng)考慮由次梁引起的主梁抗扭,或增加構(gòu)造抗扭縱筋和箍筋。(此條是從彈性計(jì)算角度出發(fā))。當(dāng)采用現(xiàn)澆板時(shí),抗扭問(wèn)題并不嚴(yán)重。

      (5).原則上梁縱筋宜小直徑小間距,有利于抗裂,但應(yīng)注意鋼筋間距要滿(mǎn)足要求,并與梁的斷面相應(yīng)。箍筋按規(guī)定在梁端頭加密。布筋時(shí)應(yīng)將縱筋等距,箍筋肢距可不等。小斷面的連續(xù)梁或框架梁,上、下部縱筋均應(yīng)采用同直徑的,盡量不在支座搭接。

      (6).端部與框架梁相交或彈性支承在墻體上的次梁,梁端支座可按簡(jiǎn)支考慮,但梁端箍筋應(yīng)加密。

      (7).考慮抗扭的梁,縱筋間距不應(yīng)大于300和梁寬,即要求加腰筋,并且縱筋和腰筋錨入支座內(nèi)La。箍筋要求同抗震設(shè)防時(shí)的要求。

      (8).反梁的板吊在梁底下,板荷載宜由箍筋承受,或適當(dāng)增大箍筋。梁支承偏心布置的墻時(shí)宜做下挑沿。

      (9).挑梁宜作成等截面(大挑梁外露者除外)。與挑板不同,挑梁的自重占總荷載的比例很小,作成變截面不能有效減輕自重。變截面挑梁的箍筋,每個(gè)都不一樣,難以施工。變截面梁的撓度也大于等截面梁。挑梁端部有次梁時(shí),注意要附加箍筋或吊筋。一般挑梁根部不必附加斜筋,除非受剪承載力不足。對(duì)于大挑梁,梁的下部宜配置受壓鋼筋以減小撓度。挑梁配筋應(yīng)留有余地。

      (10).梁上開(kāi)洞時(shí),不但要計(jì)算洞口加筋,更應(yīng)驗(yàn)算梁洞口下偏拉部分的裂縫寬度。梁從構(gòu)造上能保證不發(fā)生沖切破壞和斜截面受彎破壞。

      (11).梁凈高大于500時(shí),宜加腰筋,間距200,否則易出現(xiàn)垂直裂縫。

      (12).挑梁出挑長(zhǎng)度小于梁高時(shí),應(yīng)按牛腿計(jì)算或按深梁構(gòu)造配筋。

      (13).盡量避免長(zhǎng)高比小于4的短梁,采用時(shí)箍筋應(yīng)全梁加密,梁上筋通長(zhǎng),梁縱筋不宜過(guò)大。

      (14).扁梁寬度不必過(guò)大,只要鋼筋能正常擺下及受剪滿(mǎn)足即可。因?yàn)樵趽隙扔?jì)算時(shí),梁寬對(duì)剛度影響不大,加寬一倍,撓度減小20%左右。相對(duì)來(lái)講,增大鋼筋更經(jīng)濟(jì),鋼筋加大一倍,撓度減小60%左右,同時(shí)梁的上筋應(yīng)大部分通長(zhǎng)布置,以減小混凝土徐變對(duì)撓度的增大,如果上筋不小于下筋,撓度減小20%。

      (15).框架梁高取1/10~1/15跨度,扁梁寬可取到柱寬的兩倍。扁梁的箍筋應(yīng)延伸至另一方向的梁邊。

      (16).當(dāng)一寬框架梁托兩排間距較小的柱時(shí),可加一剛性挑梁,兩個(gè)柱支承在剛性挑梁的端頭。

      (17).梁寬大于350時(shí),應(yīng)采用四肢箍。

      七.柱詳圖:

      (1).地上為圓柱時(shí),地下部分應(yīng)改為方柱,方便施工。圓柱縱筋根數(shù)最少為8根,箍筋用螺旋箍,并注明端部應(yīng)有一圈半的水平段。方柱箍筋應(yīng)使用井字箍,并按規(guī)范加密。角柱、樓梯間柱應(yīng)增大縱筋并全柱高加密箍筋。幼兒園不宜用方柱。

      (2).原則上柱的縱筋宜大直徑大間距,但間距不宜大于200。

      (3).柱內(nèi)埋管,由于梁的縱筋錨入柱內(nèi),一般情況下僅在柱的四角才有條件埋設(shè)較粗的管。管截面面積占柱截面4%以下時(shí),可不必驗(yàn)算。柱內(nèi)不得穿暖氣管。

      (4).柱斷面不宜小于450X450,混凝土不宜小于C25,否則梁縱筋錨入柱內(nèi)的水平段不容易滿(mǎn)足0.45La的要求,不滿(mǎn)足時(shí)應(yīng)加橫筋。異型柱結(jié)構(gòu),梁縱筋一排根數(shù)不宜過(guò)多,柱端部縱筋不宜過(guò)密,否則節(jié)點(diǎn)混凝土澆筑困難。當(dāng)有部分矩形柱部分異型柱時(shí),應(yīng)注意異型柱的剛度要和矩形柱相接近,不要相差太大。

      (5).柱應(yīng)盡量采用高強(qiáng)度混凝土來(lái)滿(mǎn)足軸壓比的限制,減小斷面尺寸。

      (6).盡量避免短柱,短柱箍筋應(yīng)全高加密,短柱縱筋不宜過(guò)大。

      (7).考慮到豎向地震作用,柱子的軸壓比及配筋宜留有余地。

      (8).獨(dú)立柱上或柱的中部(半層處)有挑梁時(shí),挑梁長(zhǎng)度應(yīng)有限制。

      在用PKPM軟件計(jì)算梁柱時(shí),應(yīng)盡量采用TAT或SATWE三維軟件。相對(duì)平面框架PK來(lái)講,第一,計(jì)算結(jié)果更接近實(shí)際受力狀態(tài),如地震力或風(fēng)力是按抗側(cè)移剛度分配,而不是按框架的樓面從屬面積,還如從框架柱出挑的梁和從次梁出挑的梁,因次梁的支座(框架梁)發(fā)生下沉變形,內(nèi)力重分布,從框架柱出挑的挑梁配筋將較大。

      第二,快速方便,三維軟件整體計(jì)算,不必生成單榀框架,再人工歸并,可整樓歸并。

      第三,TAT或SATWE還可以進(jìn)行井式梁的計(jì)算,由于PKPM軟件計(jì)算梁時(shí)僅按矩形計(jì)算,而井式梁的斷面較小,有可能超筋,此時(shí)可取出彎距再按T型梁補(bǔ)充計(jì)算,不必直接加大梁高。在繪制施工圖時(shí),較大直徑的鋼筋連接宜用機(jī)械連接取代焊接,造價(jià)相差不大,但機(jī)械連接可靠并易于檢查。機(jī)械連接接頭位置可任意,但一次截?cái)嗟匿摻畈淮笥?0%,接頭位置應(yīng)錯(cuò)開(kāi)70d。

      八.重點(diǎn)注意或設(shè)計(jì)原則:

      (1).抗震驗(yàn)算時(shí)不同的樓蓋及布置(整體性)決定了采用剛性、剛?cè)?、柔性理論?jì)算??拐痱?yàn)算時(shí)應(yīng)特別注意場(chǎng)地土類(lèi)別。8度超過(guò)5層有條件時(shí),盡量加剪力墻,可大大改善結(jié)構(gòu)的抗震性能??蚣芙Y(jié)構(gòu)應(yīng)設(shè)計(jì)成雙向梁柱剛接體系,但也允許部分的框架梁搭在另一框架梁上。應(yīng)加強(qiáng)垂直地震作用的設(shè)計(jì),從震害分析,規(guī)范給出的垂直地震作用明顯不足。

      (2).雨蓬不得從填充墻內(nèi)出挑。大跨度雨蓬、陽(yáng)臺(tái)等處梁應(yīng)考慮抗扭??紤]抗扭時(shí),扭矩為梁中心線(xiàn)處板的負(fù)彎距乘以跨度的一半。

      (3).框架梁、柱的混凝土等級(jí)宜相差一級(jí)。

      (4).由于某些原因造成梁或過(guò)梁等截面較大時(shí),應(yīng)驗(yàn)算構(gòu)件的最小配筋率。

      (5).出屋面的樓電梯間不得采用磚混結(jié)構(gòu)。

      (6).框架結(jié)構(gòu)中的電梯井壁宜采用粘土磚砌筑,但不能采用磚墻承重。應(yīng)采用每層的梁承托每層的墻體重量。梯井四角加構(gòu)造柱,層高較高時(shí)宜在門(mén)洞上方位置加圈梁。因樓電梯間位置較偏,梯井采用混凝土墻時(shí)剛度很大,其它地方不加剪力墻,對(duì)梯井和整體結(jié)構(gòu)都十分不利。

      (7).建筑長(zhǎng)度宜滿(mǎn)足伸縮縫要求,否則應(yīng)采取措施。如:增大配筋率,通長(zhǎng)配筋,改善保溫,鋪設(shè)架空層,加后澆帶等。

      (8).柱子軸壓比宜滿(mǎn)足規(guī)范要求。

      (9).當(dāng)采用井字梁時(shí),梁的自重大于板自重,梁自重不可忽略不計(jì)。周邊一般加大截面的邊梁。

      (10).過(guò)街樓處的梁上筋應(yīng)通長(zhǎng),按偏拉構(gòu)件設(shè)計(jì)。

      (11).電線(xiàn)管集中穿板處,板應(yīng)驗(yàn)算抗剪強(qiáng)度或開(kāi)洞形成管井。電線(xiàn)管豎向穿梁處應(yīng)驗(yàn)算梁的抗剪強(qiáng)度。

      (12).構(gòu)件不得向電梯井內(nèi)伸出, 否則應(yīng)驗(yàn)算是否能裝下。電梯井處柱可外移或做成L型柱。

      (13).驗(yàn)算水箱下、電梯機(jī)房及設(shè)備下結(jié)構(gòu)強(qiáng)度。水箱不得與主體結(jié)構(gòu)做在一起。

      (14).當(dāng)?shù)叵滤缓芨邥r(shí),暖溝應(yīng)做防水。一般可做U型混凝土暖溝,暖氣管通過(guò)防水套管進(jìn)入室內(nèi)暖溝。有地下室時(shí),混凝土應(yīng)抗?jié)B,等級(jí)S6或S8,混凝土等級(jí)應(yīng)大于等于C25,混凝土內(nèi)應(yīng)摻入膨脹劑?;炷镣鈮?yīng)注明水平施工縫做法,一般加金屬止水片,較薄的混凝土墻做企口較難。

      (15).采用扁梁時(shí),應(yīng)注意驗(yàn)算變形。

      (16).突出屋面的樓電梯間的柱為梁托柱時(shí)應(yīng)向下延伸一層,不宜直接錨入頂層梁內(nèi),并且托梁上鐵應(yīng)適當(dāng)拉通。錯(cuò)層部位應(yīng)采取加強(qiáng)措施。女兒墻內(nèi)加構(gòu)造柱,頂部加壓頂。出入口處的女兒墻不管多高,均加構(gòu)造柱,并應(yīng)加密。錯(cuò)層處可加一大截面梁,上下層板均錨入此梁。

      (17).等基底附加壓力時(shí)基礎(chǔ)沉降并不同。

      (18).應(yīng)避免將大梁穿過(guò)較大房間,在住宅中嚴(yán)禁梁穿房間。

      (19).當(dāng)建筑布局很不規(guī)則時(shí),結(jié)構(gòu)設(shè)計(jì)應(yīng)根據(jù)建筑布局做出合理的結(jié)構(gòu)布置,并采取相應(yīng)的構(gòu)造措施。如建筑方案為兩端較大體量的建筑中間用很小的結(jié)構(gòu)相連時(shí)(啞鈴狀),此時(shí)中間很小的結(jié)構(gòu)的板應(yīng)按偏拉和偏壓考慮。板厚應(yīng)加厚,并雙層配筋。

      (20).較大跨度的挑梁下柱子內(nèi)跨梁傳來(lái)的荷載將大于梁荷載的一半。挑板道理相同。

      第五篇:鋼筋混凝土框架結(jié)構(gòu)設(shè)計(jì)的幾點(diǎn)心得體會(huì)

      鋼筋混凝土框架結(jié)構(gòu)設(shè)計(jì)的幾點(diǎn)心得體會(huì)

      摘要:在鋼筋混凝土結(jié)構(gòu)設(shè)計(jì)中,每個(gè)設(shè)計(jì)者的經(jīng)驗(yàn)不同,對(duì)規(guī)范的理解不同,所以在處理某個(gè)設(shè)計(jì)問(wèn)題時(shí),也就會(huì)采取不同的處理方法。對(duì)于鋼筋混凝土框架結(jié)構(gòu)設(shè)計(jì)中,基礎(chǔ)、梁、柱、板四部分應(yīng)注意的問(wèn)題,分別提出了幾點(diǎn)看法。

      關(guān)鍵詞:結(jié)構(gòu)設(shè)計(jì)基礎(chǔ)梁柱板

      Abstract:Inthereinforcedconcretestructuredesign,eachdesigner

      sexperienceisdifferent,theunderstandingisdifferenttothestandard,thereforewhendealswithsomedesignissue,alsocanadoptthedifferentprocessingmethod.Regardingthereinforcedconcreteportalframeconstructiondesignin,thequestionwhichthefoundation,Liang,thecolumn,theboardfourpartsshouldpayattention,proposedseveralviewsseparately.現(xiàn)在越來(lái)越多的建筑物使用鋼筋混凝土結(jié)構(gòu),故鋼筋混凝土結(jié)構(gòu)在整個(gè)建筑市場(chǎng)起到越來(lái)越重要的地位。在鋼筋混凝土結(jié)構(gòu)設(shè)計(jì)中,每個(gè)設(shè)計(jì)者的經(jīng)驗(yàn)不同,對(duì)規(guī)范的理解不同,所以在處理某個(gè)設(shè)計(jì)問(wèn)題時(shí),也就會(huì)采取不同的處理方法。在這十年的結(jié)構(gòu)設(shè)計(jì)工作中,本人也積累了一些經(jīng)驗(yàn),下面就鋼筋混凝土框架結(jié)構(gòu)設(shè)計(jì)中的基礎(chǔ)、梁、柱、板四部分,在設(shè)計(jì)時(shí)應(yīng)注意的問(wèn)題,闡述一下個(gè)人觀點(diǎn)。

      1.基礎(chǔ)部分

      1.1對(duì)于柱下擴(kuò)展基礎(chǔ)寬度較寬(大于4米)或地基不均勻及地基較軟時(shí)宜采用柱下條基。并應(yīng)考慮節(jié)點(diǎn)處基礎(chǔ)底面積雙向重復(fù)使用的不利因素,適當(dāng)加寬基礎(chǔ)。

      1.2建筑地段較好,基礎(chǔ)埋深大于3米時(shí),應(yīng)建議甲方做地下室。當(dāng)?shù)鼗休d力滿(mǎn)足設(shè)計(jì)要求時(shí),地下室底板可不再外伸以利于防水。每隔30~40米設(shè)一后澆帶,并注明兩個(gè)月后用微膨脹混凝土澆注。設(shè)置地下室可降低地基的附加應(yīng)力,提高地基的承載力(尤其是在周?chē)薪ㄖr(shí)有用),減少地震作用對(duì)上部結(jié)構(gòu)的影響。不應(yīng)設(shè)局部地下室,且地下室應(yīng)有相同的埋深。

      1.3地下室外墻為混凝土?xí)r,相應(yīng)的樓層處梁和基礎(chǔ)梁可取消。

      1.4抗震縫、伸縮縫在地面以下可不設(shè),連接處應(yīng)加強(qiáng)。但沉降縫兩側(cè)墻體基礎(chǔ)一定要分開(kāi)。

      1.5新建建筑物基礎(chǔ)不宜深于周?chē)延谢A(chǔ)。如深于原有基礎(chǔ),其基礎(chǔ)間的凈距應(yīng)不少于基礎(chǔ)高差的2倍,否則應(yīng)打抗滑移樁,防止原有建筑的破壞。建筑層數(shù)相差較大時(shí),應(yīng)在層數(shù)較低的基礎(chǔ)方格中心的區(qū)域內(nèi)墊焦碴來(lái)調(diào)整基底附加應(yīng)力。

      1.6獨(dú)立基礎(chǔ)偏心不能過(guò)大,必要時(shí)可與相近的基礎(chǔ)做成柱下條基。柱下條形基礎(chǔ)的底板偏心不能過(guò)大,必要時(shí)可作成三面支承一面自由板(類(lèi)似筏基中間開(kāi)洞)。兩根柱的柱下條基的荷載重心和基礎(chǔ)底版的形心宜重合,基礎(chǔ)底板可做成梯形或臺(tái)階形,或調(diào)整挑梁兩端的出挑長(zhǎng)度。

      1.7獨(dú)立基礎(chǔ)的拉梁宜通長(zhǎng)配筋,其下應(yīng)墊焦碴。拉梁頂標(biāo)高宜較高,否則底層墻體過(guò)高。

      1.8底層內(nèi)隔墻一般不用做基礎(chǔ),可將地面的混凝土墊層局部加厚。

      1.9考慮到一般建筑沉降為鍋底形,結(jié)構(gòu)的整體彎曲和上部結(jié)構(gòu)與基礎(chǔ)的協(xié)同作用,頂、底板鋼筋應(yīng)拉通(多層的負(fù)筋可截?cái)?/2或1/3),且縱向基礎(chǔ)梁的底筋也應(yīng)拉通。

      1.10基礎(chǔ)底板混凝土不宜大于C3O,一是沒(méi)用,二是容易出現(xiàn)裂縫。

      1.11基礎(chǔ)底面積不應(yīng)因地震附加力而過(guò)分加大,否則地震下安全了而常規(guī)情況下反而沉降差異較大,本末倒置。

      2.柱部分

      2.1地上為圓柱時(shí),地下部分應(yīng)改為方柱,方便施工。圓柱縱筋根數(shù)最少為8根,箍筋用螺旋箍,并注明端部應(yīng)有一圈半的水平段。方柱箍筋應(yīng)使用井字箍,并按規(guī)范加密。角柱、樓梯間柱應(yīng)增大縱筋并全柱高加密箍筋。幼兒園不宜用方柱。

      2.2原則上柱的縱筋宜大直徑大間距,但間距不宜大于

      200。

      2.3柱內(nèi)埋管,由于梁的縱筋錨入柱內(nèi),一般情況下僅在柱的四角才有條件埋設(shè)較粗的管。管截面面積占柱截面4%以下時(shí),可不必驗(yàn)算。柱內(nèi)不得穿暖氣管。

      2.4柱斷面不宜小于450×450,混凝土不宜小于C25,否則梁縱筋錨入柱內(nèi)的水平段不容易滿(mǎn)足0.45La的要求,不滿(mǎn)足時(shí)應(yīng)加橫筋;否則在梁柱節(jié)點(diǎn)處鋼筋太密,混凝土澆筑困難。異型柱結(jié)構(gòu),梁縱筋一排根數(shù)不宜過(guò)多,柱端部縱筋不宜過(guò)密,否則節(jié)點(diǎn)混凝土澆筑困難。當(dāng)有部分矩形柱部分異型柱時(shí),應(yīng)注意異型柱的剛度要和矩形柱相接近,不要相差太大。

      2.5柱應(yīng)盡量采用高強(qiáng)度混凝土來(lái)滿(mǎn)足軸壓比的限制,減小斷面尺寸。

      2.6盡量避免短柱,短柱箍筋應(yīng)全高加密,短柱縱筋不宜過(guò)大。

      2.7考慮到豎向地震作用,柱子的軸壓比及配筋宜留有余地。

      2.8獨(dú)立柱上或柱的中部(半層處)有挑梁時(shí),挑梁長(zhǎng)度應(yīng)有限制。

      3.梁部分

      3.1梁上有次梁處(包括挑梁端部)應(yīng)附加箍筋和吊筋,宜優(yōu)先采用附加箍筋。附加筋一般要有,但不應(yīng)絕對(duì)。規(guī)范說(shuō)的清楚,位于梁下部或梁截面高度范圍內(nèi)的集中荷載,應(yīng)全部由附加橫向鋼筋承擔(dān)。也就是說(shuō),位于梁上的集中力如梁上柱、梁上后做的梁如水箱下的墊梁不必加附加筋。位于梁下部的集中力應(yīng)加附加筋。但梁截面高度范圍內(nèi)的集中荷載可根據(jù)具體情況而定。當(dāng)主次梁截面相差不大,次梁荷載較大時(shí),應(yīng)加附加筋。當(dāng)主梁高度很高,次梁截面很小、荷載很小時(shí),如快接近板上附加暗梁,主梁可不加附加筋。還有當(dāng)主次梁截面均很大,如工藝要求形成的主次深梁,而荷載相對(duì)不大,主梁也可不加附加筋。

      3.2當(dāng)外部梁跨度相差不大時(shí),梁高宜等高,尤其是外部的框架梁。當(dāng)梁底距外窗頂尺寸較小時(shí),宜加大梁高做至窗頂。外部框架梁盡量做成外皮與柱外皮平齊。梁也可偏出柱邊一較小尺寸。梁與柱的偏心可大于1/4柱寬,并宜小于1/3

      柱寬。

      3.3梁上有次梁時(shí),應(yīng)避免次梁搭接在主梁的支座附近,否則應(yīng)考慮由次梁引起的主梁抗扭,或增加構(gòu)造抗扭縱筋和箍筋。當(dāng)采用現(xiàn)澆板時(shí),抗扭問(wèn)題并不嚴(yán)重。

      3.4原則上梁縱筋宜小直徑小間距,有利于抗裂,但應(yīng)注意鋼筋間距要滿(mǎn)足要求,并與梁的斷面相應(yīng)。箍筋按規(guī)定在梁端頭加密。布筋時(shí)應(yīng)將縱筋等距,箍筋肢距可不等。小斷面的連續(xù)梁或框架梁,上、下縱筋均應(yīng)采用同直徑的,盡量不在支座搭接。

      3.5端部與框架梁相交或彈性支承在墻體上的次梁,梁端支座可按簡(jiǎn)支考慮,但梁端箍筋應(yīng)加密。

      3.6上反梁的板吊在梁底下,板荷載宜由箍筋承受,或適當(dāng)增大箍筋。梁支承偏心布置的墻時(shí)宜做下挑沿。

      3.7挑梁宜作成等截面(大挑梁外露者除外)。與挑板不同,挑梁的自重占總荷載的比例很小,作成變截面不能有效減輕自重。變截面挑梁的箍筋,每個(gè)都不一樣,難以施工。變截面梁的撓度也大于等截面梁。挑梁端部有次梁時(shí),注意

      要附加箍筋或吊筋。一般挑梁根部不必附加斜筋,除非受剪承載力不足。對(duì)于大挑梁,梁的下部宜配置受壓鋼筋以減小撓度。挑梁配筋應(yīng)留有余地。

      3.8梁上開(kāi)洞時(shí),不但要計(jì)算洞口加筋,更應(yīng)驗(yàn)算梁洞口下偏拉部分的裂縫寬度。梁從構(gòu)造上能保證不發(fā)生沖切破壞和斜截面受彎破壞。

      3.9挑梁出挑長(zhǎng)度小于梁高時(shí),應(yīng)按牛腿計(jì)算或按深梁構(gòu)造配筋。

      3.10扁梁寬度不必過(guò)大,只要鋼筋能正常擺下及受剪滿(mǎn)足即可。因?yàn)樵趽隙扔?jì)算時(shí),梁寬對(duì)剛度影響不大,加寬一倍,撓度減小20%左右。相對(duì)來(lái)講,增大鋼筋更經(jīng)濟(jì),鋼筋加大一倍,撓度減小60%左右,同時(shí)梁的上筋應(yīng)大部分通長(zhǎng)布置,以減小混凝土徐變對(duì)撓度的增大,如果上筋不小于下筋,撓度減小20%。

      3.11當(dāng)一寬框架梁托兩排間距較小的柱時(shí),可加一剛性挑梁,兩個(gè)柱支承在剛性挑梁的端頭。

      3.12梁寬大于350時(shí),應(yīng)采用四肢箍。

      4.現(xiàn)澆板部分

      4.1板的鋼筋宜采用大直徑大間距,但間距不大于200,間距盡量用200。(一般跨度小于6.6米的板的裂縫均可滿(mǎn)足要求)。板上下鋼筋間距宜相等,直徑可不同,但鋼筋直徑類(lèi)型也不宜過(guò)多。

      4.2相連幾個(gè)房間的同型號(hào)同間距板底鋼筋宜連通。

      4.3配筋計(jì)算時(shí),可考慮塑性?xún)?nèi)力重分布,將板上筋乘以0.8~0.9的折減系數(shù),將板下筋乘以1.1~1.2的放大系數(shù)。

      4.4支承在外圈框架梁上的板負(fù)筋不宜過(guò)大,否則將對(duì)梁產(chǎn)生過(guò)大的附加扭距。一般:板厚150時(shí)采用φ10@200;否則用φ8@200。

      4.5當(dāng)厚板與薄板相接時(shí),薄板支座按固定端考慮是適當(dāng)?shù)模癜寰筒缓线m,宜減小厚板支座配筋,增大跨中配筋。

      4.6非矩形板宜減小支座配筋,增大跨中配筋。

      4.7室內(nèi)輕隔墻下一般不應(yīng)加粗鋼筋,一是輕隔墻有可能移位,二是板整體受力,應(yīng)整體提高板的配筋。只有垂直單向板長(zhǎng)邊的不可能移位的隔墻,如廁所與其他房間的隔墻下才可以加粗鋼筋。

      下載淺談框架結(jié)構(gòu)設(shè)計(jì)的心得體會(huì)word格式文檔
      下載淺談框架結(jié)構(gòu)設(shè)計(jì)的心得體會(huì).doc
      將本文檔下載到自己電腦,方便修改和收藏,請(qǐng)勿使用迅雷等下載。
      點(diǎn)此處下載文檔

      文檔為doc格式


      聲明:本文內(nèi)容由互聯(lián)網(wǎng)用戶(hù)自發(fā)貢獻(xiàn)自行上傳,本網(wǎng)站不擁有所有權(quán),未作人工編輯處理,也不承擔(dān)相關(guān)法律責(zé)任。如果您發(fā)現(xiàn)有涉嫌版權(quán)的內(nèi)容,歡迎發(fā)送郵件至:645879355@qq.com 進(jìn)行舉報(bào),并提供相關(guān)證據(jù),工作人員會(huì)在5個(gè)工作日內(nèi)聯(lián)系你,一經(jīng)查實(shí),本站將立刻刪除涉嫌侵權(quán)內(nèi)容。

      相關(guān)范文推薦

        教學(xué)樓框架結(jié)構(gòu)設(shè)計(jì)結(jié)束語(yǔ)

        結(jié)束語(yǔ) 通過(guò)畢業(yè)設(shè)計(jì),我不僅溫習(xí)了以前在課堂上學(xué)習(xí)的專(zhuān)業(yè)知識(shí),同時(shí)我也得到了老師和同學(xué)的幫助,學(xué)習(xí)和體會(huì)到了建筑結(jié)構(gòu)設(shè)計(jì)的基本技能和思想。特別值得一提的是,我深深的認(rèn)識(shí)......

        教學(xué)樓框架結(jié)構(gòu)設(shè)計(jì)參考文獻(xiàn)

        參考文獻(xiàn) [1] GB 50009-2001(2006版),建筑結(jié)構(gòu)荷載規(guī)范[S]. [2] GB 50010-2002,混凝土結(jié)構(gòu)設(shè)計(jì)規(guī)范[S]. [3] GB 50011-2001(2008版),建筑抗震設(shè)計(jì)規(guī)范[S]. [4] GB 50083-2002,建......

        框架結(jié)構(gòu)設(shè)計(jì)計(jì)算書(shū).

        第一章 緒論 第一節(jié) 工程概況 一、工程設(shè)計(jì)總概況: 1. 規(guī)模:本工程是一棟四層鋼筋混凝土框架結(jié)構(gòu)教學(xué)樓,使用年限為 50年 , 抗震設(shè)防烈度為 8度; 建筑面積約 3000㎡, 建筑平......

        淺談混凝土框架結(jié)構(gòu)設(shè)計(jì)要點(diǎn)心得

        龍?jiān)雌诳W(wǎng) http://.cn 淺談混凝土框架結(jié)構(gòu)設(shè)計(jì)要點(diǎn)心得 作者:郭瑞 來(lái)源:《建筑與文化》2013年第01期 【摘 要】隨著我國(guó)建筑業(yè)前所未有的發(fā)展,建筑設(shè)計(jì)結(jié)構(gòu)成為了建設(shè)單位所關(guān)......

        淺談我國(guó)多層混凝土框架結(jié)構(gòu)設(shè)計(jì)(最終定稿)

        淺談我國(guó)多層混凝土框架結(jié)構(gòu)設(shè)計(jì) 1.前言 隨著社會(huì)的發(fā)展,鋼筋混凝土框架結(jié)構(gòu)的建筑物越來(lái)越普遍.由于鋼筋混凝土結(jié)構(gòu)與砌體結(jié)構(gòu)相比較具有承載力大、結(jié)構(gòu)自重輕、抗震性能好......

        異形柱框架結(jié)構(gòu)設(shè)計(jì)小結(jié)★

        異形柱框架結(jié)構(gòu)設(shè)計(jì)小結(jié) 本人曾設(shè)計(jì)過(guò)異形柱框架結(jié)構(gòu)房屋,現(xiàn)將一些心得體會(huì)總結(jié)出來(lái),望大家批評(píng)指正. 1.異形柱框架結(jié)構(gòu)的使用范圍. 1)抗震設(shè)防裂度為7度及7度以下地區(qū); 2)......

        淺談中小學(xué)教學(xué)樓框架結(jié)構(gòu)設(shè)計(jì)要點(diǎn)[5篇]

        淺談中小學(xué)教學(xué)樓框架結(jié)構(gòu)設(shè)計(jì)要點(diǎn) 字?jǐn)?shù):1776 來(lái)源:科技致富向?qū)? 2013年7期 隨著我國(guó)國(guó)家標(biāo)準(zhǔn)《建筑工程抗震設(shè)防分類(lèi)標(biāo)準(zhǔn)》GB50223-2008、《建筑抗震設(shè)計(jì)規(guī)范》GB50011-201......

        論鋼筋混凝土框架結(jié)構(gòu)設(shè)計(jì)問(wèn)題的思考

        論鋼筋混凝土框架結(jié)構(gòu)設(shè)計(jì)問(wèn)題的思考【論文關(guān)鍵詞】:鋼筋混凝土; 框架結(jié)構(gòu); 計(jì)算簡(jiǎn)圖 【論文摘要】:針對(duì)鋼筋混凝土框架結(jié)構(gòu)的設(shè)計(jì),探討了結(jié)構(gòu)計(jì)算及設(shè)計(jì)、構(gòu)造措施方面一些需......